VFD "MIN": Flexible Shielded Motor Cable

Recommended Applications:

VFD “MIN” is a double shielded, reduced diameter motor supply cable for variable frequency drives.

Conductor:

Tinned copper.

Insulating Compound:

Multi-layer design.
Inner - Specially formulated anti surge compound.
Middle - Specially formulated PVC.
Outer - Specially formulated Nylon.

Colour Code:

Three conductors are black and white number coding, plus a green/yellow ground conductor (minimum 30% coverage) included in conductor count.

Shielding:

Inner foil shield 100% coverage.
Outer tinned copper braid 85% minimum coverage.

Jacketing Compound:

Specially formulated oil resistant black PVC.

Minimum Bend Radius:

For installation only. 7.5 x cable diameter.

Temperature Range:

For static applications -40°C to + 90°C.

Nominal Voltage Rating:

600V to 1000V.

Test Voltage:

2000V.

Resistant to:

Sunlight, UV. Suitable for direct burial and installation in wet and dry locations.

Approvals:

(UL) TYPE TC-ER, 90C, 600V, WTTC, C(UL), CIC-TC, PVC/N, FT4, 235992 CSA, AWM I/II, A/B, 90C, 600V, FT4, CE.
Flexible motor supply cable 1000V.

Domaines d’utilisation:

Le VFD «MIN» est un câble souple d’alimentation de moteur à double blindage et à diamètre réduit utilisé sur les moteurs à fréquence variable.

Conducteur:

Cuivre étamé.

Composé isolant:

Conception multicuche.
Partie interne: composé anti-surcharge
spécialement formulé.
Partie centrale: PVC spécialement formulé.
Partie externe: Nylon spécialement formulé.

Code de couleurs:

Trois conducteurs noir avec code numérique blanc, en plus d’un conducteur de terre vert/jaune (couverture minimale de 30%) compris dans le nombre de conducteurs.

Blindage:

Blindage interne en feuilles, couverture de 100%. Blindage externe en cuivre étamé tressé, couverture minimale de 85%.

Composé de gainage:

PVC noir spécialement formulé, résistant à I’huile.

Rayon minimal de courbure:

7,5 fois le diamètre du câble, à I’installation seulement.

Plage de température:

-40°C à + 90°C, en utilisation statique.

Tension nominale:

De 600V à 1000V.

Tension d’essai:

2000V.

Résistance:

Lumiére du soleil et rayons UV.
Convient à un enfouissement sans protection et
une installation en milieux humides ou secs.

Approbations:

(UL) TYPE TC-ER, 90C, 600V, WTTC, C(UL), CIC-TC, PVC/N, FT4, 235992 CSA, AWM I/II, A/B, 90C, 600V, FT4, CE.
Câble d’alimentation souple pour moteurs,1000V.

2AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4070204 2AWG 4 1.37 34.8 1513

4AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4070404 4AWG 4 1.2 30.48 1118

6AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4070604 6AWG 4 0.976 24.79 736

8AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4070804 8AWG 4 0.832 21.13 565

10AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4071004 10AWG 4 0.662 16.81 352

12AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4071204 12AWG 4 0.561 14.25 238

14AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4071404 14AWG 4 0.499 12.67 174

16AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4071604 16AWG 4 0.465 11.81 130

18AWG

Part number Stranding Conductor Outer Diameter (inches) Outer Diameter (mm) Weight Lb/1000ft PDF Sheet
4071804 18AWG 4 0.428 10.87 108